Main characteristics
Connection of SSI signal sensors of various brands
SSI signals can be redundantly connected to both the PLC's SSI module and the instrument.
Powerful signal and power anti-interference fault tolerance function, more reliable and safe
10~28 bits adjustable, Gray code, pure binary code optional
Single-turn, multi-turn absolute encoders, magnetostrictive linear sensors
Intelligent panel settings, multiple function displacement control applications
RS485 digital communication, 4-20mA, 4-8 point switch multiple output signals
appliance
Gate and valve opening control
Hydraulic cylinder stroke control
Hoist crane positioning, traveling crane positioning
Steelmaking oxygen lance positioning, converter positioning
Automatic storage, paper and textile web positioning
Automated position, length and height measurement and positioning
model number
Model: | BTM1213/RS |
Housing Material | Aluminum metal |
Overall dimensions (width, height and depth) | 160 x 80 x 170 |
Meter opening size | 152 x 75 |
Digital display digits | 6-digit digital display |
input signal | SSI Synchronous Serial Signal 10-28 bits; 1-bit External Set Signal |
Number of switching outputs | 4~8 (relay, one normally open and one normally closed for each position);panel preset, sensitivity setting, switch form setting |
scale factor | Linear Displacement Transducer Code Value Scaling Factor Setting |
Zero Setting | Any position setting, panel smart setting or external switch setting |
Orientation settings | Rotary encoder forward and reverse setting; linear displacement transducer forward and reverse setting. |
Circle Length Setting | Rotary encoder length per revolution setting; linear displacement transducer total length setting. |
signal conditioning | 4, 20mA corresponding value can be set, 4, 20mA output value can be fine-tuned zero, full |
Position signal output | 2 position signal outputs, one 4-20mA analog, one RS485 communication digital |
nonlinear setting | Multiple non-linear settings or on-site corrections are possible, and can be used for settings such as winch stacks and curved gates. |
communication protocols | Self-contained instrument protocol, can also be customized according to user-provided protocol requirements; can be set by the panel address, rate |
remote display | The output signal can be one way into the PLC, one way into the remote display meter (optional RS485 digital display meter or 4-20mA display meter). |
external power supply | Power supply for the sensor is available (specify voltage and current consumption when ordering). |
operating voltage | 220Vac (24Vdc can be customized) |
operating temperature | -10℃~60℃ |
relative humidity | <85% |
Telephone contact: 15050450799 (micro letter with number)